Webcast 02. August 2024
Professional seminar for special machine builders
07. November 2024 from 10:00 to 11:00 Clock (Time zone: Amsterdam, Berlin, Bern, Rome, Stockholm, Vienna)
CETA Testsysteme GmbH, Hilden - TEAMS Online Seminar
CETA Expert
Product group: Measuring and test technology
Register for the webcastThis online seminar covers various aspects of commissioning and reliable operation of leak and flow test stations.
In practice, the following issues arise, among others:
What methods can be used to check the test stand?
How can it be ensured that the correct test part has been correctly adapted?
What needs to be considered when carrying out series of measurements to determine the measuring equipment capability index Cg?
Are the measured values plausible and how do they relate to the test parameters?
What are the possible causes of negative measured values?
How can the measuring unit be changed to "ml/min"?
Table of contents
Checking the test stand at the operating point by automatically connecting a calibration standard
Causes of negative measured values
Conversion of the measuring unit from "Pa" to "ml/min"
Checking methods of adaptation (continuous measuring line, connection of the correct test part)
Plausibility check (measured values and test parameters)
Measuring equipment capability and determination of the Cg value during commissioning and acceptance (stabilisation time and material of the measuring line, measures to improve the Cg value)
Applications using the cycle valve (external ventilation, measuring point switchover)
Target group
This online seminar is aimed at special machine builders who have experience in the design and implementation of leak or flow test stations and would like to expand and deepen their knowledge in the areas of commissioning and reliable operation.
In practice, the following issues arise, among others:
What methods can be used to check the test stand?
How can it be ensured that the correct test part has been correctly adapted?
What needs to be considered when carrying out series of measurements to determine the measuring equipment capability index Cg?
Are the measured values plausible and how do they relate to the test parameters?
What are the possible causes of negative measured values?
How can the measuring unit be changed to "ml/min"?
Table of contents
Checking the test stand at the operating point by automatically connecting a calibration standard
Causes of negative measured values
Conversion of the measuring unit from "Pa" to "ml/min"
Checking methods of adaptation (continuous measuring line, connection of the correct test part)
Plausibility check (measured values and test parameters)
Measuring equipment capability and determination of the Cg value during commissioning and acceptance (stabilisation time and material of the measuring line, measures to improve the Cg value)
Applications using the cycle valve (external ventilation, measuring point switchover)
Target group
This online seminar is aimed at special machine builders who have experience in the design and implementation of leak or flow test stations and would like to expand and deepen their knowledge in the areas of commissioning and reliable operation.